V-Shaped Dry Cooling Tower


Natural wind enters the cooling tower through the intake grille, flows upward, and is discharged above the cooling tower through the exhaust system.

Keywords:

V-Shaped Dry Cooling Tower

Consult

Product details

V -Type cooling tower is a industrial cooling equipment which with highly efficient  water saving .Its core design centers around V shaped arranged cooling tube bundles. By optimizing air flow and heat exchange area, they excel in water conservation,noise  reduction,and compactness.

V-Type Design The cooling tower's cooling tube bundles are arranged in a V-shaped, tilted arrangement  (typically at an angle of 60°-120°), with a fan unit mounted on top to create forced  convection. This design significantly improves space utilization: compared to traditional  vertical arrangements, the floor space required for the same heat exchange area is reduced  by 30%-50%, making it particularly suitable for industrial environments with limited space.

Meet the cooling needs in multiple fields 

Low Noise and Low Maintenance

The number of fans is reduced by 30%-50%, and combined with silencer ducts, operating  noise is below 75dB. The modular design allows individual tube bundles to be removed and  replaced independently, reducing maintenance costs by 40%.

Power Industry

It replaces traditional wet cooling towers for cooling turbine condenser water in thermal and  nuclear power plants. For example, a 300MW thermal power unit using a V-shaped dry cooling  tower saves approximately 1.2 million tons of water annually while meeting environmental  emission requirements.

Data Center and Mining Machine Cooling 

In field tests with Antminer S21 mining machines, the ChainForce V-shaped dry cooling tower  consistently controls chip temperatures below 40°C, achieving a 30% energy saving compared  to water-cooling solutions and water treatment system is not required.

 

ModelBoundary dimension(mm)Volume (L)Fan Qty (set)Operation  power (KW)Water flow (L/min)Environment  temperature (℃)Water outlet  temperature (℃)
      
150KW22002250230018023250DtDt+△t
240KW28002250230024024.8400DtDt+△t
350KW32002500250030048.8580DtDt+△t
500KW380025002500336613.2800DtDt+△t
600KW450025002500420614.41000DtDt+△t
800KW540025002750580819.21330DtDt+△t
1000KW62002500275072010241600DtDt+△t
1250KW7500250027509001228.82050DtDt+△t
1400KW82002500275010001433.62300DtDt+△t
1600KW95002500275011001638.42600DtDt+△t
1800KW108002500275012501843.23000DtDt+△t
2000KW1200025002750140020483300DtDt+△t
 Note: ①Dry cooler ideal work conditions:Dry bulb temperature about 30℃, the humidity about 60%. ②Above the default set with water curtain , the water curtain thickness is 15cm. ③Value of the △t is :5℃-10℃。(Dt is the dry bulb temperature 、△t is the closed temperature、  Dt+△t is the water outlet temperature.)